Technishield 50
- Fire Resistance:
- E30, E60
- Profile
- 50mm x 70mm
- Door set:
- Single
- Minimum
- 1800mm
- Maximum
- 3000mm
- Minimum
- 955mm
- Maximum
- 1230mm

Fire-rated glass partitions and doors delivering 30 to 120 minutes of certified protection, without compromising design.
The Technishield range delivers high-performing fire-rated glass partitions and doors that meet the visual and practical demands of modern office design. From slim aluminium profiles to robust steel-framed systems, every product is engineered to provide certified fire protection while maintaining the aesthetic of your workspace.
From 30 to 120 minutes of integrity and insulation, the Technishield range meets the most demanding fire safety requirements with European E and EI rated systems.
Achieve up to Rw47dB acoustic ratings using standard fire-rated glass products, with enhanced performance available through additional lamination or double-glazed units.
Available as screens, single and double doors, side panels, and over panels, with butt-jointed, mullion, or fully framed glazing options to suit any elevation.



Every Technishield system is rigorously tested to the highest standards. Acoustic performance is measured on full-height, multi-module screens with glazing joints and perimeter trackwork, not simplified window samples, ensuring the ratings you specify are the ratings you get on site.
Fire ratings conform to European classification standards (EN 13501-2) with integrity (E) and insulation (I) ratings from 30 to 120 minutes.
Technishield systems are listed on the National Building Specification for straightforward specification by architects and designers.
All acoustic performance data is laboratory tested in UKAS-accredited facilities, with full test reports available on request.
Acoustic testing follows the FIS Acoustic Verification Scheme requirements for real-world, full-height multi-module screen testing.

Technishield systems are specified across a wide range of commercial environments where fire compartmentation, escape route protection, and design quality are all essential.
We offer a wide range of finishes for our glass partitions and door frames. Explore a selection of colours and textures that add another layer of individuality to every space.

The Technishield 50, 65 and 70 systems each include compatible fire-rated door sets. Select a configuration to compare specifications and size limits across all three systems.
The range covers E30 (30 minutes integrity) through to EI120 (120 minutes integrity and insulation). Technishield 25 and 54 offer E30, Technishield 50 offers up to E60, Technishield 65 offers EI30/EI60, Technishield 70 offers EI90, and Technishield 110 offers up to EI120.
E-rated systems (integrity only) prevent the passage of flames and hot gases. EI-rated systems provide both integrity and insulation, also limiting heat transfer through the partition. EI ratings are required where people may be close to the barrier.
Acoustic ratings range from Rw37dB with single glazed systems up to Rw47dB with the Technishield 110. Enhanced ratings are achievable through lamination or double glazing.
Yes — Technishield 50, 65, and 70 all include door options. Single doors, double doors, doors with over panels, and doors with side panels are available depending on the system.
Glass panels can be connected via 5mm fire-rated silicone butt joints (available in grey, white, or black) or vertical mullions for a fully framed appearance.
Yes — all systems are tested in UKAS-accredited laboratories. Acoustic testing follows FIS Acoustic Verification Scheme requirements using full-height, multi-module screens.